58 changes: 40 additions & 18 deletions dashboard.py
Original file line number Diff line number Diff line change
Expand Up @@ -45,29 +45,40 @@ def channel_name(index: int) -> str:
return f"Channel {channel_label(index)}"


# Total row width = 1916. Vertical guides (from left):
# x = w_be — Oil | Process Monitor lines up with Beam Energy | Cathode Heating
# x = w_bp — Process Monitor | Messages lines up with Beam Pulse | Main Control
# Top-row slice widths: Vacuum+Oil = w_be; ProcessMonitor+Messages = w_ch; PM width = w_bp - w_be.
frames_config = [
# Row 0
# Row 0 — safety strip (full width)
("Interlocks", 0, 1916, 41),

# Row 1
("Oil System", 1, 604, 130),
("Beam Steering", 1, 778, 130),
("Beam Energy", 1, 528, 130),
# Row 1 — Vacuum | Oil | Process Monitor | Messages (left → right)
("Vacuum System", 1, 350, 400),
("Oil System", 1, 350, 400),
("Process Monitor", 1, 258, 400),
("Messages Frame", 1, 958, 400),

# Row 2
("Vacuum System", 2, 604, 438),
("Beam Pulse", 2, 777, 438),
("Main Control", 2, 529, 438),
# Row 2 — Beam Energy | Cathode Heating (w_be + w_ch = 1916)
("Beam Energy", 2, 700, 400),
("Cathode Heating", 2, 1216, 400),

# Row 4
("Process Monitor", 3, 339, 458),
("Cathode Heating", 3, 1041, 458),
("Messages Frame", 3, 539, 458),
# Row 3 — Beam Pulse | Main Control (w_bp + w_mc = 1916)
("Beam Pulse", 3, 958, 450),
("Main Control", 3, 958, 450),

# Row 5
("Machine Status", 4, 1916, 38)
# Row 4 — machine status
("Machine Status", 4, 1916, 38),
]


def _messages_frame_layout():
"""Return (row, width, height) for the Messages Frame entry in frames_config."""
for title, row, w, h in frames_config:
if title == "Messages Frame":
return row, w, h
raise RuntimeError("frames_config must include 'Messages Frame'")

class EBEAMSystemDashboard:
"""
Main dashboard class that manages the EBEAM System Control Dashboard interface.
Expand Down Expand Up @@ -351,7 +362,8 @@ def create_frames(self):
if title == "Main Control":
self.create_main_control_notebook(frame)

self.rows[3].add(self.messages_frame.frame, stretch='always')
_msg_row, _, _ = _messages_frame_layout()
self.rows[_msg_row].add(self.messages_frame.frame, stretch='always')
self.frames['Messages Frame'] = self.messages_frame.frame

def create_main_control_notebook(self, frame):
Expand Down Expand Up @@ -992,6 +1004,11 @@ def create_subsystems(self):
com_ports=self.com_ports,
logger=self.logger,
active = self.machine_status_frame.MACHINE_STATUS
),
'Beam Energy': subsystem.BeamEnergySubsystem(
self.frames['Beam Energy'],
com_ports=self.com_ports,
logger=self.logger
)
}

Expand Down Expand Up @@ -1054,7 +1071,8 @@ def create_subsystems(self):

def create_messages_frame(self):
"""Create a scrollable frame for displaying system messages and errors."""
self.messages_frame = MessagesFrame(self.rows[3], width = frames_config[-2][2], height = frames_config[-2][3])
_msg_row, _msg_w, _msg_h = _messages_frame_layout()
self.messages_frame = MessagesFrame(self.rows[_msg_row], width=_msg_w, height=_msg_h)
self.logger = self.messages_frame.logger

def create_machine_status_frame(self):
Expand Down Expand Up @@ -1138,7 +1156,9 @@ def create_com_port_frame(self, parent_frame):
self.port_selections = {}
self.port_dropdowns = {}

for subsystem in ['VTRXSubsystem', 'CathodeA PS', 'CathodeB PS', 'CathodeC PS', 'TempControllers', 'Interlocks', 'ProcessMonitors']:
for subsystem in [
'VTRXSubsystem', 'CathodeA PS', 'CathodeB PS', 'CathodeC PS',
'TempControllers', 'Interlocks', 'ProcessMonitors', 'KnobBox']:
frame = ttk.Frame(self.com_port_menu)
frame.pack(fill=tk.X, padx=5, pady=2)
ttk.Label(frame, text=f"{subsystem}:").pack(side=tk.LEFT)
Expand Down Expand Up @@ -1198,6 +1218,8 @@ def update_com_ports(self, new_com_ports):
subsystem.update_com_port(new_com_ports.get('VTRXSubsystem'))
elif subsystem_name == 'Cathode Heating':
subsystem.update_com_ports(new_com_ports)
elif subsystem_name == 'Beam Energy':
subsystem.update_com_port(new_com_ports)
else:
self.logger.warning(f"Subsystem {subsystem_name} does not have an update_com_port method")
self.logger.info(f"COM ports updated: {self.com_ports}")
Expand Down
191 changes: 191 additions & 0 deletions instrumentctl/knob_box/README.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,191 @@
# Knob Box Driver Documentation

This README documents the dashboard-side Knob Box integration in `instrumentctl/knob_box/`.

### System Overview

The Knob Box is the operator panel and local monitoring/interlock interface for four high-voltage supplies:

- `+1 kV` Matsusada
- `-1 kV` Matsusada
- `+20 kV` Bertan
- `+3 kV` Bertan

On the hardware side, the system is split into:

- Four monitoring Arduinos that read supply telemetry and expose it on RS-485 / Modbus RTU
- One Logic Arduino that enforces beam/interlock behavior

Only the monitoring Arduinos speak Modbus. The Logic Arduino is visible to the dashboard only through the `+3 kV` monitoring Arduino, which republishes live logic state and latched fault history in its Modbus register map.

Inside this dashboard repo:

- `knob_box_modbus.py` polls all four monitor Arduinos over one RS-485 serial port
- `subsystem/beam_energy/beam_energy.py` consumes that data and updates the GUI

### Hardware / Serial Summary

| Item | Value |
|------|-------|
| Physical transport | RS-485 |
| Protocol | Modbus RTU |
| Active dashboard driver | `KnobBoxModbus` |
| Dashboard COM-port key | `KnobBox` |
| Baud rate | `9600` |
| Data bits | `8` |
| Parity | `N` |
| Stop bits | `1` |
| Default timeout | `0.5 s` |
| Modbus unit IDs | `1-4` |

### Power Supply / Unit Mapping

| Unit ID | Supply | Role in dashboard |
|---------|--------|-------------------|
| `1` | `+1 kV` Matsusada | Local telemetry plus Matsusada reset-state indication |
| `2` | `-1 kV` Matsusada | Local telemetry plus Matsusada reset-state indication |
| `3` | `+20 kV` Bertan | Local telemetry |
| `4` | `+3 kV` Bertan | Local telemetry plus Logic Arduino state, flags, and handshake status |

### Current Dashboard Integration

The current dashboard path is:

```python
from instrumentctl.knob_box.knob_box_modbus import KnobBoxModbus
```

`KnobBoxModbus` is not exported from `instrumentctl/__init__.py`, so callers must import it from the full module path.

#### Constructor Parameters

| Parameter | Default | Meaning |
|-----------|---------|---------|
| `port` | required | Serial COM port for the RS-485 adapter |
| `baudrate` | `9600` | Modbus baud rate |
| `timeout` | `0.5` | Read timeout in seconds |
| `parity` | `"N"` | Serial parity |
| `stopbits` | `1` | Serial stop bits |
| `bytesize` | `8` | Serial data bits |
| `logger` | `None` | Optional dashboard logger |
| `debug_mode` | `True` | Stored flag for debug-oriented behavior/logging |

#### Core Methods Used by the Dashboard

| Method | Purpose |
|--------|---------|
| `connect()` | Open the Modbus serial client with exponential reconnect backoff |
| `disconnect()` | Close the Modbus serial client |
| `poll_all()` | Poll all four unit IDs, rotating start order each pass |
| `get_data_snapshot()` | Return a copy of the latest per-unit data |
| `get_unit_connection_status(uid)` | Report whether a unit has polled successfully within `CONNECTION_TIMEOUT` |
| `any_unit_connected()` | Report whether any unit has polled successfully within `CONNECTION_TIMEOUT` |
| `close()` | Compatibility alias that calls `disconnect()` |

#### Basic Usage

```python
from instrumentctl.knob_box.knob_box_modbus import KnobBoxModbus

knob_box = KnobBoxModbus(port="COM13")

if knob_box.connect():
snapshot = knob_box.poll_all()
unit_4 = snapshot[4]
print(unit_4["actual_voltage_V"])
print(unit_4["logic_alive"])

knob_box.close()
```

#### Polling and Reconnect Behavior

- `UNIT_IDS` is fixed to `[1, 2, 3, 4]`
- `poll_all()` rotates the unit polling order so the same device is not always last
- Each unit read is attempted up to `3` times before that unit is marked failed for the current pass
- Failed unit polls back off exponentially from `0.5 s` up to `5.0 s`
- Failed connection attempts also back off exponentially from `0.5 s` up to `5.0 s`
- Connection freshness is based on `last_success` timestamps, not just whether the serial port is open
- `CONNECTION_TIMEOUT` is `10.0 s`; if a unit has not answered within that window, the dashboard treats that unit as disconnected

#### How `BeamEnergySubsystem` Uses It

`subsystem/beam_energy/beam_energy.py` instantiates `KnobBoxModbus` using the COM port stored under the `KnobBox` key in the dashboard COM-port configuration.

The subsystem then:

- Starts a polling thread that calls `poll_all()` every `0.2 s`
- Calls `get_data_snapshot()` during UI refresh
- Calls `get_unit_connection_status(uid)` to decide whether to show live data or placeholder values
- Calls `any_unit_connected()` to decide when to trigger reconnect behavior
- Refreshes the UI every `500 ms`

If no unit has reported successfully within `CONNECTION_TIMEOUT`, the subsystem falls back to placeholder values and starts reconnect logic.

### Modbus Register Contract

The current driver expects one contiguous block of six input registers from each unit:

| Address | Constant | Meaning |
|---------|----------|---------|
| `0` | `IREG_V_SET_ADDR` | Set voltage in integer volts |
| `1` | `IREG_V_READ_ADDR` | Measured voltage in integer volts |
| `2` | `IREG_I_READ_ADDR` | Measured current in integer microamps |
| `3` | `IREG_3KV_RESET_COUNT_ADDR` | `+3 kV` timer/reset-event counter |
| `4` | `DINPUT_UNLATCHED_SIGNALS_ADDR` | Packed unlatched signals word |
| `5` | `DINPUT_LATCHED_FLAGS_ADDR` | Packed latched flags word |

Registers `0-5` are all read through Modbus function code `04` in one request per unit.

#### Unlatched Signals Word (`register 4`)

| Bit | Mask | Driver field | Meaning |
|-----|------|--------------|---------|
| `0` | `UNLATCHED_SIGNAL_MASK_HVENABLE` | raw `hv_enable` source for units `1-3` | Local HV enable switch telemetry |
| `1` | `UNLATCHED_SIGNAL_MASK_RESET_STATE_1KV` | `reset_state_1kV` | Matsusada inferred reset/overcurrent state |
| `2` | `UNLATCHED_SIGNAL_MASK_ARM80KV_ENABLE` | `arm_80kV` | Raw `Arm 80kV` switch state from the `+3 kV` monitor path |
| `3` | `UNLATCHED_SIGNAL_MASK_CCSPOWER_ENABLE` | `ccs_power` | Logic Arduino CCS enable output mirror on unit `4` |
| `4` | `UNLATCHED_SIGNAL_MASK_ARMBEAMS_ENABLE` | `arm_beams` | Logic Arduino Arm Beams output mirror on unit `4` |
| `5` | `UNLATCHED_SIGNAL_MASK_3KV_ENABLE` | `3kV_enable` | Logic Arduino `3 kV` enable output mirror on unit `4` |
| `6` | `UNLATCHED_SIGNAL_MASK_NOMOP` | `nomop_flag` | Logic Arduino Nominal Operation flag on unit `4` |
| `7` | `UNLATCHED_SIGNAL_MASK_LOGIC_ALIVE` | `logic_alive` | Logic alive heartbeat derived from D9 ack-back edge detection |

#### Latched Flags Word (`register 5`)

| Bit | Mask | Driver field | Meaning |
|-----|------|--------------|---------|
| `4` | `LATCHED_FLAG_MASK_3KV_TIMER` | `timer_state_3kV` | `3 kV` timer event occurred since the last ACK cycle |
| `5` | `LATCHED_FLAG_MASK_ARMBEAMS_SWITCH` | `armbeams_flag` | Arm Beams switch asserted since the last ACK cycle |
| `6` | `LATCHED_FLAG_MASK_CCSPOWER_ALLOW` | `ccspower_flag` | CCS Power Allow switch asserted since the last ACK cycle |
| `7` | `LATCHED_FLAG_MASK_ARM80KV_SWITCH` | `arm80kv_flag` | Arm 80 kV switch asserted since the last ACK cycle |
| `8` | `LATCHED_FLAG_MASK_1K_VCOMP` | `vcomp_1k_flag` | `+1 kV` voltage comparator fault since the last ACK cycle |
| `9` | `LATCHED_FLAG_MASK_1K_ICOMP` | `icomp_1k_flag` | `+1 kV` current comparator fault since the last ACK cycle |
| `10` | `LATCHED_FLAG_MASK_NEG_1K_VCOMP` | `neg_vcomp_1k_flag` | `-1 kV` voltage comparator fault since the last ACK cycle |
| `11` | `LATCHED_FLAG_MASK_NEG_1K_ICOMP` | `neg_icomp_1k_flag` | `-1 kV` current comparator fault since the last ACK cycle |
| `12` | `LATCHED_FLAG_MASK_20K_VCOMP` | `vcomp_20k_flag` | `+20 kV` voltage comparator fault since the last ACK cycle |
| `13` | `LATCHED_FLAG_MASK_20K_ICOMP` | `icomp_20k_flag` | `+20 kV` current comparator fault since the last ACK cycle |
| `14` | `LATCHED_FLAG_MASK_3K_VCOMP` | `vcomp_3k_flag` | `+3 kV` voltage comparator fault since the last ACK cycle |
| `15` | `LATCHED_FLAG_MASK_3K_ICOMP` | `icomp_3k_flag` | `+3 kV` current comparator fault since the last ACK cycle |

Bits `0-3` are currently unused.

#### Important Decoding Rules

- `actual_current_mA` is derived from register `2` by dividing the integer microamp value by `1000.0`
- `3kv_reset_count` is only meaningful for unit `4`; other units should normally report `0`
- `arm_beams` and `ccs_power` are live Logic Arduino output mirrors on the `+3 kV` path, not raw switch inputs
- For unit `4`, `hv_enable` is intentionally overridden to use `3kV_enable` instead of the raw HV-enable switch bit

That unit-`4` special case matters because the Beam Energy panel uses `hv_enable` for the `Output` indicator. For the `+3 kV` supply, that indicator therefore reflects the logic-authorized enable output, not just the front-panel request switch.


#### Exposed Data Shape

`get_power_supply_data()` returns a copy of:

| Key | Meaning |
|-----|---------|
| `set_voltage` | Parsed set voltage as `float` or `None` |
| `meas_voltage` | Parsed measured voltage as `float` or `None` |
| `meas_current` | Parsed measured current as `float` or `None` |
| `connected` | Serial connection state |
Loading