Hitachi Yutaki – Separate Heating/Cooling Sensors & Critical Fixes (v2.0.0-beta.5)

Downloads for this release

This release introduces separate thermal energy sensors for heating and cooling, providing accurate energy tracking and fixing critical setup issues. This is a breaking change that improves COP calculation accuracy by filtering defrost cycles and properly separating heating from cooling operations.

✨ What's New?

  • Separate Thermal Energy Sensors: The integration now provides explicit sensors for heating and cooling operations:

    • Real-time Power:
      • thermal_power_heating: Heating power output (when ΔT > 0) in kW
      • thermal_power_cooling: Cooling power output (when ΔT < 0) in kW - only created for units with cooling circuits
    • Daily Energy (auto-reset at midnight):
      • thermal_energy_heating_daily: Daily heating energy production in kWh
      • thermal_energy_cooling_daily: Daily cooling energy production in kWh - cooling circuits only
    • Total Cumulative Energy:
      • thermal_energy_heating_total: Total heating energy production in kWh
      • thermal_energy_cooling_total: Total cooling energy production in kWh - cooling circuits only
  • Improved Thermal Energy Calculation Logic: Fixes issue #123 with a complete rewrite of the thermal energy calculation:

    • Heating/Cooling Separation: Now correctly separates heating (ΔT > 0) from cooling (ΔT < 0) operations
    • Defrost Cycle Filtering: Defrost cycles are now filtered and not counted as energy production, eliminating false cooling energy measurements
    • Compressor-Based Measurement: Only measures energy produced by the heat pump when the compressor is running
    • Universal Logic: Works automatically for heating circuits, DHW, and pool based on water temperature delta
    • Accurate COP Calculations: This results in accurate COP calculations (previously inflated by counting defrost as production)
  • Recorder Dependency: Added recorder dependency to manifest for proper Home Assistant validation and to ensure compatibility with data rehydration features.

🔧 Bug Fixes

  • Setup Failure Fix: Fixed setup failure when configuration parameters are missing by adding the required translation_key parameter to async_create_issue and corresponding translations. This resolves issue #146 where the integration would fail to create repair issues during configuration.

  • Hassfest Validation Fix: Fixed hassfest validation error by adding missing recorder dependency to manifest. This ensures the integration passes all Home Assistant validation checks.

⚠️ Breaking Changes

  • Thermal Energy Sensor Migration Required: The old thermal energy sensors are now deprecated (disabled by default, but still available for backward compatibility):
    • thermal_power → use thermal_power_heating instead
    • daily_thermal_energy → use thermal_energy_heating_daily instead
    • total_thermal_energy → use thermal_energy_heating_total instead
    • Action Required: Update your Energy Dashboard configurations and automations to use the new sensor names
    • Why Deprecated: The old sensors counted defrost cycles and lacked heating/cooling separation, resulting in incorrect COP values

📚 Technical Improvements

  • ThermalPowerService Enhancement: New service implementation with separate heating and cooling power tracking:

    • Automatic mode detection based on temperature delta (ΔT)
    • Defrost cycle filtering to prevent false measurements
    • Compressor state validation before energy calculation
    • Universal logic applicable to all thermal circuits (heating, DHW, pool, cooling)
  • ThermalEnergyAccumulator Updates: Enhanced accumulator with separate tracking for heating and cooling:

    • Independent energy counters for heating and cooling modes
    • Proper state restoration after Home Assistant restarts
    • Daily reset logic for daily energy sensors
  • Sensor Entity Builder: Updated thermal sensor builder to conditionally create cooling sensors only when cooling circuits are detected, reducing unnecessary entities for heating-only installations.

  • Improved Measurement Accuracy: The new calculation logic ensures:

    • Only real energy production is measured (compressor must be running)
    • Defrost cycles don't inflate energy production values
    • Heating and cooling are properly separated for accurate tracking
    • COP calculations reflect true heat pump performance

📝 Important Notes

  • Migration Required: After upgrading to this version, you must update your Energy Dashboard and any automations that reference the old thermal energy sensors:

    • Replace thermal_power with thermal_power_heating
    • Replace daily_thermal_energy with thermal_energy_heating_daily
    • Replace total_thermal_energy with thermal_energy_heating_total
    • If you have cooling circuits, add the new cooling sensors to your dashboard
  • COP Accuracy Improvement: The filtering of defrost cycles means your COP values may change compared to previous versions. This is expected and reflects more accurate performance measurements.

  • Cooling Sensor Availability: Cooling sensors (thermal_power_cooling, thermal_energy_cooling_daily, thermal_energy_cooling_total) are only created for units that have cooling circuits configured. If you don't see these sensors, your unit may not support cooling mode.

  • Backward Compatibility: The old sensors remain available (disabled by default) for a transition period, but they will be removed in a future release. Please migrate to the new sensors as soon as possible.

  • Recorder Dependency: This release requires Home Assistant's Recorder to be enabled for proper operation of data rehydration features (introduced in beta.4).

🧪 Testing Needed

We would appreciate feedback on:

  • Sensor Migration: Verify that the new heating/cooling sensors appear correctly and provide accurate measurements.

  • Energy Dashboard: Confirm that your Energy Dashboard continues to work after migrating to the new sensor names.

  • COP Accuracy: Check that COP values are now more accurate and don't show inflated values during defrost cycles.

  • Cooling Circuits: If you have cooling circuits, verify that cooling sensors are created and track cooling energy correctly.

  • Setup Process: Test the setup/configuration flow to ensure the translation_key fix resolves setup failures.

  • Defrost Filtering: Monitor during defrost cycles to confirm that energy production is correctly paused (not counted).

🐛 Bug Reports

If you encounter any issues, please open a GitHub issue and include:

  • Your Home Assistant version.
  • Your configuration (heat pump model, gateway type, cooling circuits if configured).
  • Debug-level logs (especially for thermal energy calculations and sensor creation).
  • A clear description of the problem and reproduction steps.
  • Information about whether you've migrated from the old sensors to the new ones.

🙏 Acknowledgments

Thanks to the community for their feedback and contributions:

  • Special Thanks: A special thank you to @Neuvidor for their investigation and contributions around COP calculation and thermal energy measurement, which were instrumental in improving the accuracy of these features.

  • Issues Resolved:

    • #123 - Thermal energy calculation improvements
    • #146 - Setup failure fix
  • Beta Testers: Thank you to all testers providing feedback on the v2.0.0-beta releases.