Notifications
You must be signed in to change notification settings - Fork 62
Open
Labels
Description
Is there an existing issue for this?
- I have searched the existing issues
Used Hardware?
Wemos D1 Mini
What happened?
Using latest version 2.0.0-Pre7. In my invertor when Charge_Source_Priority = Solar + Utility it does not charge from main line (do not know about solar as it is not present in my setup) but when I switch to Charge_Source_Priority = Only solar charging permitted (03 in PI30 communication protocol) invertor starts charing from main line.
I can provide more info if you need it
Screenshots / Fotos
Steps To Reproduce
Explained above
Version
1.x.x and above
Relevant livejson output
{"EspData":{},"DeviceData":{"AC_In_Rating_Voltage":230,"AC_In_Rating_Current":18.2,"AC_Out_Rating_Voltage":230,"AC_Out_Rating_Frequency":50,"AC_Out_Rating_Current":18.2,"AC_Out_Rating_Apparent_Power":4200,"AC_Out_Rating_Active_Power":4200,"Battery_Rating_Voltage":24,"Battery_Recharge_Voltage":23.5,"Battery_Under_Voltage":23.6,"Battery_Bulk_Voltage":28.2,"Battery_Float_Voltage":28,"Battery_Type":"User","Current_Max_AC_Charging_Current":40,"Current_Max_Charging_Current":110,"Input_Voltage_Range":"UPS","Output_Source_Priority":"Utility first","Charger_Source_Priority":"Solar + Utility","Parallel_Max_Num":1,"Machine_Type":"Off Grid","Topology":"Transformerless","Output_mode":0,"Battery_Redischarge_Voltage":27,"PV_OK_Condition_For_Parallel":0,"PV_Power_Balance":1,"Device_Model":"VMII-NXPW5KW"},"LiveData":{}}What browsers are you seeing the problem on?
no Issue with the Browser or WebUI
Reactions are currently unavailable