Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathpoller.go
More file actions
266 lines (223 loc) · 6.53 KB
/
poller.go
File metadata and controls
266 lines (223 loc) · 6.53 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
package main
import (
"fmt"
"math"
"os"
"sync"
"time"
"github.com/simonvetter/modbus"
)
const (
UINT16 uint = 1
INT16 uint = 2
UINT32 uint = 3
INT32 uint = 4
FLOAT32 uint = 5
)
// The Target object describes a target data value.
type Target struct {
MbType modbus.RegType // modbus register type:
// either modbus.HOLDING_REGISTER
// or modbus.INPUT_REGISTER
ValueType uint // how to decode the value after reading it from
// the modbus device (e.g. UINT16, FLOAT32, etc.)
UnitId uint8 // modbus device unit ID (slave ID)
RegAddr uint16 // base modbus register address
Label string // (text) label describing the value
ScaleFactor float64 // scale factor applied to the value (disabled if 0)
Offset float64 // offset applied to the value (disabled if 0)
DecimalPlaces uint // round the to x decimal places (disabled if 0)
}
type PollerConfiguration struct {
Url string // modbus client target URL
// (e.g. tcp://somehost:502 or rtu:///dev/ttyUSB0)
Targets []*Target // target values to query on this modbus link
PollInterval time.Duration // how long to wait between target polls
Timeout time.Duration // modbus request timeout parameter
Endianness modbus.Endianness // endianness of the modbus registers:
// either modbus.BIG_ENDIAN or modbus.LITTLE_ENDIAN
WordOrder modbus.WordOrder // word order of modbus registers for 32-bit
// values: either modbus.HIGH_WORD_FIRST
// or modbus.LOW_WORD_FIRST
// serial link parameters:
Speed uint // baud rate
DataBits uint // number of data bits per character
StopBits uint // number of stop bits
Parity uint // parity: modbus.PARITY_NONE, modbus.PARITY_ODD or
// modbus.PARITY_EVEN
}
// Poller pbject.
type Poller struct {
conf *PollerConfiguration
lock sync.Mutex
mc *modbus.ModbusClient
points []*Point
}
// Returns a new poller.
func NewPoller(conf *PollerConfiguration) (p *Poller, err error) {
p = &Poller{
conf: conf,
}
p.mc, err = modbus.NewClient(&modbus.ClientConfiguration{
URL: conf.Url,
Speed: conf.Speed,
DataBits: conf.DataBits,
Parity: conf.Parity,
StopBits: conf.StopBits,
Timeout: conf.Timeout,
})
if err != nil {
return
}
go p.poll()
return
}
// Returns a slice containing all buffered points and clears the local buffer.
func (p *Poller) Points() (res []*Point) {
p.lock.Lock()
res = p.points
p.points = p.points[:0]
p.lock.Unlock()
return
}
// Reads, decodes and transforms target values every conf.PollInterval.
// The modbus link (either TCP or RTU) is reconnected automaticaly whenever an
// unrecoverable i/o error is encountered (i.e. if the error is neither a timeout nor
// a modbus error).
// Values read are stored as Point objects in an internal slice and can be collected
// using the Points() method above.
func (p *Poller) poll() {
var ticker *time.Ticker
var err error
var mcOpen bool
var failedAttempts uint
var value interface{}
var u16 uint16
var u32 uint32
var f64 float64
ticker = time.NewTicker(p.conf.PollInterval)
for {
<-ticker.C
if !mcOpen {
err = p.mc.Open()
if err != nil {
fmt.Printf("failed to open modbus link %s: %v\n",
p.conf.Url, err)
// sleep for a capped exponential time to avoid hammering the
// network/serial line with retries
if failedAttempts < 5 {
failedAttempts++
}
time.Sleep(time.Duration(failedAttempts * 5) * time.Second)
continue
}
failedAttempts = 0
mcOpen = true
fmt.Printf("modbus link %s open\n", p.conf.Url)
}
for _, target := range p.conf.Targets {
// set the modbus unit ID
p.mc.SetUnitId(target.UnitId)
switch target.ValueType {
case UINT16, INT16:
u16, err = p.mc.ReadRegister(target.RegAddr, target.MbType)
// decode as signed if required
if target.ValueType == INT16 {
value = int16(u16)
} else {
value = u16
}
case UINT32, INT32:
u32, err = p.mc.ReadUint32(target.RegAddr, target.MbType)
// decode as signed if required
if target.ValueType == INT32 {
value = int32(u32)
} else {
value = u32
}
case FLOAT32:
value, err = p.mc.ReadFloat32(target.RegAddr, target.MbType)
default:
fmt.Printf("unsupported register type '%v'\n", target.ValueType)
}
if err != nil {
fmt.Printf("failed to read target '%s': %v\n",
target.Label, err)
// if the error is most likely not recoverable,
// close the modbus link to force a reconnect
if !isRecoverableError(err) {
p.mc.Close()
mcOpen = false
break
}
continue
}
// apply transforms, if any
// note: any use of Offset, ScaleFactor or DecimalPlaces
// converts the value to float64
if target.ScaleFactor != 0 ||
target.Offset != 0 ||
target.DecimalPlaces != 0 {
// type conversion
switch value.(type) {
case uint16: f64 = float64(value.(uint16))
case int16: f64 = float64(value.(int16))
case int32: f64 = float64(value.(int32))
case uint32: f64 = float64(value.(uint32))
case float32: f64 = float64(value.(float32))
}
// apply the scale factor
if target.ScaleFactor != 0 {
f64 *= target.ScaleFactor
}
// apply the offset
if target.Offset != 0 {
f64 += target.Offset
}
// round to target.DecimalPlaces decimal places
if target.DecimalPlaces != 0 {
f64 = round(f64, target.DecimalPlaces)
}
value = f64
}
p.lock.Lock()
// turn the value into a Point object and add it to the poller's
// internal buffer
p.points = append(p.points,
&Point{
Timestamp: time.Now().UTC(),
Label: target.Label,
Value: value,
})
p.lock.Unlock()
}
}
return
}
// Rounds a value to the specified number of decimal places.
func round(val float64, places uint) (res float64) {
var shift float64 = math.Pow10(int(places))
if val >= 0 {
res = math.Floor((val * shift) + 0.5) / shift
} else {
res = math.Floor((val * shift) - 0.5) / shift
}
return
}
// Returns true if the error is recoverable in the sense that
// it does not require the poller to re-establish the modbus link.
func isRecoverableError(err error) (yes bool) {
if err == modbus.ErrIllegalFunction ||
err == modbus.ErrIllegalDataAddress ||
err == modbus.ErrIllegalDataValue ||
err == modbus.ErrServerDeviceFailure ||
err == modbus.ErrMemoryParityError ||
err == modbus.ErrServerDeviceBusy ||
err == modbus.ErrGWPathUnavailable ||
err == modbus.ErrGWTargetFailedToRespond ||
err == modbus.ErrRequestTimedOut ||
os.IsTimeout(err) {
yes = true
}
return
}